HOME> Products> Miscellaneous> Others> MRMplus Retention Time Marker

MRMplus Retention Time Marker

Date:June 21 2017Web Page No:80768

MRM plus logo

MRMplus Retention Time Marker is the mixture of marker peptides (12 synthetic peptides) for calculating the retention times of LC in LC-MS/MS system for scheduled-MRM. The segment value of each MRMplus Standard Peptide is easily converted by using this marker and the conversion software.

example data

Component

200 x MRMplus Retention Time Marker Stock Solution (12 µl)

*Dilute 1 µl of Stock Solution into 199 µl of sample diluent for your LC system as Working Solution. When you use TFA as the sample diluent, grass ampule type product (eg. #28902 from Thermo Scientific) is recommended. Working Solution should be stored at 4ºC
NOTE: AVOID FREEZE-THAW CYCLES for the stock solution
NOTE: Please use working solution within ONE WEEK

Go back to index

General Protocol

*This protocol is optimized for QTRAP5500 System (nanoESI, ABSciex). For the other LC-MS/MS systems, optimal condition should be determined by users.

  1. Inject 0.2 µl of the Working Solution into LC.
  2. Optimize LC conditions and injection volume.
  3. Input the values of Q1 and Q3 for 12 marker peptides and conduct MRM analysis without scheduling function.
  4. Write down the detected retention time of 12 marker peptides into spread sheet.
  5. Convert segment values of internal standard peptides specific to your target proteins into expected retention time using the detected retention time and conversion software (RTimeToSegment.exe).
  6. Input the expected retention time into your LC-MS/MS system.
  7. Mix 1 µl Retention Time Marker for 1 µg sample, and then add the suitable amount of internal standard peptide. Dilute the mixture to 10 µl with sample diluent, use 2 µl for conduct scheduled MRM analysis.

NOTE: You can find the information of the Q1, Q3 values, and conversion software (RTimeToSegment.exe) on FUNAKOSHI website (http://www.funakoshi.co.jp/contents/7979).
NOTE: You should set a wide range of expected retention time for scheduling, or you would miss the target peptide. NOTE: Some marker peptides may appear closely each other or sometimes interchanged depending on your LC conditions, such as gradient, colums used, or room temperature.

Go back to index

Reference

  • A large-scale targeted proteomics assay resource based on an in vitro human proteome, Nature Methods, 10.1038/nmeth.4116

[Date : February 15 2024 12:37]

Detail Product Name Product Code Supplier Size Price
MRMplus Retention Time Marker
DatasheetThis may not be the latest data sheet.
FMR-002 FMRFunakoshi Co.,Ltd. 12 µl $150

Description MRMplus Retention Time Marker is the mixture of marker peptides (12 synthetic peptides) for calculating the retention times of LC in LC-MS/MS system for scheduled-MRM. The segment value of each MRMplus Standard Peptide is easily converted by using this marker and the conversion software.
Storage -80°C CAS
Link

Quantitative proteomics tools & analysis service by iMPAQT method

[Date : February 15 2024 12:37]

MRMplus Retention Time Marker


  • Product Code: FMR-002
  • Supplier: FMR
  • Size: 12µl
  • Price: $150

Description MRMplus Retention Time Marker is the mixture of marker peptides (12 synthetic peptides) for calculating the retention times of LC in LC-MS/MS system for scheduled-MRM. The segment value of each MRMplus Standard Peptide is easily converted by using this marker and the conversion software.
Storage -80°C CAS
Link

Quantitative proteomics tools & analysis service by iMPAQT method

Go back to index

CONTACT

export@funakoshi.co.jp

  • Prices are for USA / Canada customers. Prices do not include shipping and handling charges, VAT, import tariffs and service charge etc.
  • Please note that Product Information or Price may change without notice.